| Flow Rate Range | Applicable Settings | Recommendation Notes |
|---|---|---|
| 150 - 300 ml/min | Home Wellness & Daily Care | Ideal for personal or family daily wellness routines, improving sleep quality, and relieving fatigue; offers lightweight hydrogen-oxygen inhalation with simple, user-friendly operation. |
| 600 - 1200 ml/min | 1200 ml/min Wellness Centers / Advanced Home Care | Suitable for post-workout recovery, complementary management of chronic conditions, community health centers, and similar settings, meeting more advanced wellness requirements. |
| 1500 - 3000 ml/min | Clinics / Rehabilitation Centers | Designed for professional medical facilities, Traditional Chinese Medicine (TCM) clinics, pain management centers, and similar environments; supports continuous, rotating use by multiple individuals with stable and reliable performance |
| 5000 - 7500 ml/min | Spas / High-End Wellness Clubs | Tailored for large-scale spas, anti-aging centers, and exclusive wellness clubs; capable of simultaneously supporting hydrogen baths and hydrogen inhalation for multiple users. |
Suyzeko offers a range of gas flow rate options
Suyzeko offers a range of gas flow rate options, ranging from 150 ml/min to 7500 ml/min. The equipment utilizes advanced SPE (Solid Polymer Electrolyte) water electrolysis technology, ensuring high hydrogen production efficiency, exceptional gas purity (free of impurities), stable performance, and a long operational lifespan. Equipped with a medical-grade power adapter and integrated with high-quality electrolytic cell core components, the device guarantees safe and stable operation. Operating at noise levels below 50 dB—meeting "sleep-grade" silent standards—the unit ensures that use in a bedroom or during the night will not disturb rest. Key components come with a three-year warranty, reflecting the product’s stable and reliable quality and providing distributors with premium products that stand the test of the market. The equipment has obtained authoritative international certifications— including CE, FCC, UL, PSE, and RoHS—meeting market entry standards for major regions across Europe, the Americas, and Asia, thereby facilitating worry-free export and market promotion for our clients.
High-Quality Electrolytic Cell
The initial voltage of each electrolytic cell plate is below 1.7V—far exceeding industry standards. Utilizing imported proton exchange membranes, the system achieves complete separation of hydrogen and oxygen, resulting in a hydrogen purity level of 99.99%.
High-Definition Large-Screen LCD Interface
Equipped with a high-definition LCD display, the device provides real-time readouts of information such as gas flow rate, operating duration, and error alerts. The interface is user-friendly and features simple one-touch operation.
Superior Heat Dissipation
Featuring brushless fans, high-density ventilation ports, and an optimized airflow channel design, the unit boasts excellent heat dissipation capabilities. This ensures the device can meet the demands of high-intensity, prolonged usage, making it ideal for high-frequency application scenarios.
Product Certifications




Principle
1. Selective Antioxidant Action (Core Mechanism)
This constitutes the most renowned and fundamental principle of molecular hydrogen medicine. Unlike traditional antioxidants that scavenge free radicals "indiscriminately," hydrogen gas exhibits selectivity:
Precise Scavenging: Hydrogen gas selectively neutralizes the most toxic free radicals within the human body—specifically, the hydroxyl radical (⋅OH) and the peroxynitrite anion (ONOO−).
Preservation of Beneficial Signals: It does not react with reactive oxygen species (ROS) that serve vital physiological signaling functions—such as hydrogen peroxide (H2O2) and nitric oxide (NO)—thereby maintaining normal cellular signal transduction.
2. Anti-inflammatory Effects
Studies indicate that hydrogen gas can significantly modulate the body’s inflammatory response:
Inhibition of Inflammatory Factors: Hydrogen gas can lower serum levels of pro-inflammatory cytokines (e.g., IL-1β, IL-6, TNF-α).
Regulation of Signaling Pathways: By inhibiting key pro-inflammatory signaling pathways—such as NF-κB—it alleviates tissue damage caused by chronic inflammation.
3. Anti-apoptotic and Cytoprotective Effects
Hydrogen gas protects vital organs by intervening in cellular apoptotic processes:
Mitochondrial Stabilization: Hydrogen gas can enter mitochondria, reducing the oxidative damage generated within them and maintaining cellular energy metabolism.
Inhibition of Apoptotic Pathways: It regulates the expression of apoptosis-related proteins, thereby preventing secondary cell death caused by ischemia-reperfusion injury (e.g., following the restoration of blood flow after a myocardial infarction or cerebral infarction).
4. Signal Modulation and Gene Expression
Hydrogen gas acts not merely as a direct scavenger, but also as a "regulatory switch":
Activation of Endogenous Antioxidant Systems: Hydrogen gas activates the Nrf2 signaling pathway, thereby inducing the body to endogenously produce increased quantities of antioxidant substances, such as superoxide dismutase (SOD) and glutathione.
Metabolic Regulation: Clinical studies have demonstrated that hydrogen gas can improve glucose and lipid metabolism; by regulating the secretion of adipokines, it serves as an adjunctive therapy for diabetes and metabolic syndrome.
5. Exceptional Biological Permeability (Physicochemical Advantage)
This constitutes a unique physical advantage that distinguishes hydrogen from other therapeutic agents:
Unimpeded Diffusion: As the smallest molecule in nature, hydrogen readily permeates cell membranes—even crossing the blood-brain barrier and the placental barrier—to access the cell nucleus and mitochondria. This property endows it with potential therapeutic value for neurological disorders (such as Alzheimer’s disease and Parkinson’s disease).
6.Regulation of Gut Microbiota
Recent studies suggest that hydrogen may act as a mediator to promote systemic health by remodeling the microenvironment of the gut microbiota and increasing the abundance of beneficial bacteria.
Note: OEM customization is supported; the flow rate can be flexibly adjusted within the 7,500 ml/min range according to specific requirements.
Applicable locations






OEM/ODM Support
We offer comprehensive OEM/ODM support services, backed by over 13 years of industry experience in R&D and manufacturing, and hold ISO13485 and ISO9001 certifications. Our in-house R&D team is fully equipped to fulfill a wide range of customization requirements, including product design, color selection, control system user interface design, gas flow rate specifications, brand logo customization, and packaging design.
Frequently Asked Questions
More info on different use scenarios of the device can be for your kind reference, as follows: For the daily health care, total inhalation of hydrogen and oxygen mixed gas for about 0.5-1 hour perday is required. Inhalation for several times will bring better effects for anti-oxidant, remaining beauty and keeping young, staying healthy.
Yes, for larger gas flow rate like 1500ml and above, it has gas flow rate adjustment function. It makes the machine cover more using scenario. And when using, we believe hydrogen oxygen mixed gas is more useful and effective.
The devices are designed with special fire blocks in different parts. This is technical issues which are not open for ordinary consumers.
We have PEM membrane, and it is mixed gas of hydrogen oxygen.
More than five years. But the whole period depends on many factors, maintenance, personal use behaviors, etc.
Both. Two nasal cannulas, two breathing tubes. We also have other options can provide, you can ask for personalization requires.
To connect the gas output and nasal mask.
Directly to the gas output
Our nasal cannulas are specially designed for our device and of high quality. And we do not recommend others due to the safety factor.
Yes. 7 days or so, according to the quantity.
It will continue work.8000 hours is just the guarantee period, and in fact it can be used much longer in case the device is well maintained. These days we are working to prove the device can be used much more than 5000 hours by new reliability test and life expectation. It is planned to send the device back to maintain the main parts of the device (excluding the accessories) free of charge during the gurantee period. But probably the freight charge will be divided equally for both parts. We planned for a maintenance for every 2500 hours, the first of which is free for the main structure. For the main structure of the device, I believe there will be no problems to continue to use, but for some accessories, they need to be maintained. But if the device is working well, it is unnecessary to send back for maintenance.